Saz B., Yumuşak G., Doganay Ozyilmaz O.
FRONTIERS IN MATERIALS, cilt.13, ss.1-8, 2026 (SCI-Expanded, Scopus)
-
Yayın Türü:
Makale / Tam Makale
-
Cilt numarası:
13
-
Basım Tarihi:
2026
-
Doi Numarası:
10.3389/fmats.2026.1864365
-
Dergi Adı:
FRONTIERS IN MATERIALS
-
Derginin Tarandığı İndeksler:
Science Citation Index Expanded (SCI-EXPANDED), Scopus
-
Sayfa Sayıları:
ss.1-8
-
Anahtar Kelimeler:
elastic modulus, elemental mapping, nanoindentation, SEM-EDX, XRD, zirconia dental implant
-
Marmara Üniversitesi Adresli:
Evet
Özet
This preliminary specimen-level study characterized single specimens from two commercially available zirconia dental implant materials using nanoindentation, SEM-EDX, and XRD. The aim was to document local mechanical response, elemental composition, and qualitative phase-related features, and to provide preliminary implant-specific material information that may be considered in future simulation-based studies. One implant specimen from each commercial system was evaluated. Repeated nanoindentation measurements were obtained from different locations on metallographically prepared sections, while surface morphology and elemental composition were examined by SEM-EDX using a ZEISS EVO10 scanning electron microscope equipped with a Bruker XFlash Detector 730M-250 EDX system. Phase-related features were assessed qualitatively by XRD in the 2θ range of 20°–70°. Repeated local nanoindentation measurements yielded descriptive hardness and indentation elastic modulus values for the two specimens. Z1 showed a hardness of 17.23 ± 0.87 GPa and an indentation elastic modulus of 223.7 ± 7.6 GPa based on 10 measurements, whereas Z2 showed a hardness of 17.96 ± 1.01 GPa and an indentation elastic modulus of 246.2 ± 7.4 GPa based on eight measurements; in both cases, the SD reflects local spatial variability within a single specimen rather than between-specimen variability. SEM-EDX analyses showed Zr–O–Y-based elemental profiles in both specimens, while a trace Al signal was observed only in Z1 by EDX spectrum and elemental mapping. The XRD patterns of both specimens showed broadly similar zirconia-based reflections within the limits of qualitative comparison. These findings should be interpreted as preliminary specimen-level observations rather than statistically generalizable commercial-system data. The measured values may be useful as preliminary material inputs for future sensitivity-based simulation studies, provided that they are considered together with validated literature data and appropriate model-specific assumptions.