Atıf İçin Kopyala
Tumasyan A., Adam W., Andrejkovic J. W., Bergauer T., Bloch D., Chatterjee S., ...Daha Fazla
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, cilt.1037, 2022 (SCI-Expanded)
-
Yayın Türü:
Makale / Tam Makale
-
Cilt numarası:
1037
-
Basım Tarihi:
2022
-
Doi Numarası:
10.1016/j.nima.2022.166795
-
Dergi Adı:
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
-
Derginin Tarandığı İndeksler:
Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, Aerospace Database, Analytical Abstracts, Aquatic Science & Fisheries Abstracts (ASFA), Artic & Antarctic Regions, Chemical Abstracts Core, INSPEC, Public Affairs Index, DIALNET
-
Anahtar Kelimeler:
CMS, Detector, Alignment, Tracker, Legacy reprocessing, MillePede-II, HipPy, VERTEX
-
Marmara Üniversitesi Adresli:
Evet
Özet
The strategies for and the performance of the CMS silicon tracking system alignment during the 2015-2018 data-taking period of the LHC are described. The alignment procedures during and after data taking are explained. Alignment scenarios are also derived for use in the simulation of the detector response. Systematic effects, related to intrinsic symmetries of the alignment task or to external constraints, are discussed and illustrated for different scenarios.