A Useful Method for the Practice of Pneumatic Retinopexy: Slit-Lamp Laser Photocoagulation through the Gas Bubble
JOURNAL OF PERSONALIZED MEDICINE, cilt.13, sa.5, 2023 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 13 Sayı: 5
- Basım Tarihi: 2023
- Doi Numarası: 10.3390/jpm13050741
- Dergi Adı: JOURNAL OF PERSONALIZED MEDICINE
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, Food Science & Technology Abstracts, Directory of Open Access Journals
- Anahtar Kelimeler: laser retinopexy, pneumatic retinopexy, retinal detachment, sulfur hexafluoride, wide-field contact lens
- Marmara Üniversitesi Adresli: Evet
Özet
This study aimed to demonstrate the laser retinopexy method through the gas bubble under a slit-lamp biomicroscope using a wide-field contact lens to treat rhegmatogenous retinal detachment (RRD) with pneumatic retinopexy (PR) and report its anatomical and functional results. This single-center, retrospective case series included RRD patients treated with PR using sulfur hexafluoride (SF6). The demographics, preoperative factors, and anatomical and functional outcomes were collected from the patient files. The single-procedure success rate of PR at postoperative 6th months was 70.8% (17/24 eyes), and the final success rate after secondary surgeries was 100%. The BCVA was better in the successful PR eyes at postoperative 3rd (p = 0.011) and 6th month (p = 0.016) than in failed eyes. No single preoperative factor was associated with PR success. The single-procedure success rate of PR using the laser retinopexy method through the gas bubble with a wide-field contact lens system seems comparable to the PR literature.