Assessment of Reliability of Three Indices Measuring Gingival Overgrowth Procjena pouzdanosti triju indeksa za mjerenje hiperplazije gingive


Creative Commons License

Alkateb A. S., ÖZTÜRK ÖZENER H., KURU L.

Acta Stomatologica Croatica, cilt.57, sa.2, ss.98-112, 2023 (ESCI) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 57 Sayı: 2
  • Basım Tarihi: 2023
  • Doi Numarası: 10.15644/asc57/2/1
  • Dergi Adı: Acta Stomatologica Croatica
  • Derginin Tarandığı İndeksler: Emerging Sources Citation Index (ESCI), Scopus, Central & Eastern European Academic Source (CEEAS), EMBASE, Directory of Open Access Journals
  • Sayfa Sayıları: ss.98-112
  • Anahtar Kelimeler: Gingival Overgrowth, Index, Inflammation, Photography
  • Marmara Üniversitesi Adresli: Evet

Özet

Objectives: Numerous indices have been used to grade the severity of gingival overgrowth which led to suspicion regarding the results concerning its prevalence and pathogenicity. The aim of this study was to assess the concordance of three different gingival overgrowth indices, which were used wide-ly in previous studies, and check their reliability and reproducibility. Material and Methods: A total of 30 full-mouth plaster casts and 90 intra-oral photographs collected from 30 patients diagnosed with gingival overgrowth were included in our study. Three trained examiners performed measurements twice on plaster casts using gingival hyperplasia index (A index) and hyperplastic index (B index). In-traoral photographs were assessed also twice using (C index). Results: Concordance of intra-exam-iner and inter-examiner reliability of the recorded measurements was carried out for each index using weighted kappa (K), with a confidence interval of 95%. The A index revealed intra-examiner total kappa values between 0.724-0.876 for horizontal measurement and 0.512-0.823 for vertical mea-surement, and inter-examiner total kappa values between 0.255-0.626 horizontally and 0.235-0.279 vertically. The B index presented intra-examiner total kappa values between 0.587-0.868 horizontally and 0.653-0.855 vertically; and inter-examiner total kappa values between 0.393-0.595 and 0.372-0.635 for horizontal and vertical measurements, respectively. The C index achieved the highest intra-examiner concordance with total kappa values between 0.758-0.855 and inter-examiner total kappa values between 0.716-0.804. Conclusions: The C index evaluated through intraoral photographs is considered the most reliable and applicable method to be utilized. The C index is suggested to be used in large scale populations with its definite detailed criteria.