Reduction of nosocomial infections in the intensive care unit using an electronic hand hygiene compliance monitoring system
JOURNAL OF INFECTION IN DEVELOPING COUNTRIES, cilt.15, sa.12, ss.1923-1928, 2021 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 15 Sayı: 12
- Basım Tarihi: 2021
- Doi Numarası: 10.3855/jidc.14156
- Dergi Adı: JOURNAL OF INFECTION IN DEVELOPING COUNTRIES
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, BIOSIS, CAB Abstracts, EMBASE, MEDLINE, Veterinary Science Database, Directory of Open Access Journals
- Sayfa Sayıları: ss.1923-1928
- Anahtar Kelimeler: Electronic hand hygiene recording and reminder system, healthcare-associated infection, hand hygiene, compliance
- Açık Arşiv Koleksiyonu: AVESİS Açık Erişim Koleksiyonu
- Marmara Üniversitesi Adresli: Evet
Özet
Introduction: Healthcare-associated infection is an important cause of mortality and morbidity worldwide. Well-regulated infection control and hand hygiene are the most effective methods for preventing healthcare-associated infections. This study evaluated and compared conventional hand hygiene observation and an electronic hand-hygiene recording and reminder system for preventing healthcare-associated infections. Methodology: This pre-and post-intervention study, employed an electronic hand-hygiene recording and reminder system for preventing healthcare-associated infections at a tertiary referral center. Healthcare-associated infection surveillance was recorded in an anesthesia and reanimation intensive care unit from April 2016 to August 2016. Hand-hygiene compliance was observed by conventional observation and an electronic recording and reminder system in two consecutive 2-month periods. healthcare-associated infections were calculated as incidence rate ratios. Results: The rate of healthcare-associated infections in the electronic hand-hygiene recording and reminder system period was significantly decreased compared with that in the conventional hand-hygiene observation period (incidence rate ratio = 0.58; 95% confident interval = 0.33-0.98). Additionally, the rate of central line-associated bloodstream infections and the rate of ventilator-associated pneumonia were lower during the electronic hand hygiene recording and reminder system period (incidence rate ratio= 0.41; 95% confident interval = 0.11-1.30 and incidence rate ratio = 0.67; 95% confident interval = 0.30-1.45, respectively). Conclusions: After implementing the electronic hand hygiene recording and reminder system, we observed a significant decrease in healthcare-associated infections and invasive device-associated infections. These results were encouraging and suggested that electronic hand hygiene reminder and recording systems may reduce some types of healthcare-associated infections in healthcare settings.